ASTM A90/A90M(). Standard Test Method for Weight [Mass] of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings. ASTM A ZINC PLATING WEIGHT ON STEEL. This test method covers procedures for determining the weight [mass] of coating on iron or steel sheet, wire, and. A. ASTM A90 – Standards Test Method for Weight of Coating on F. ASTM A — Steel Sheet, Zinc Coated (Galvanized) or Zinc-Iron Alloy.

Author: Faerisar Tesida
Country: Morocco
Language: English (Spanish)
Genre: History
Published (Last): 1 June 2013
Pages: 458
PDF File Size: 6.78 Mb
ePub File Size: 16.71 Mb
ISBN: 241-2-14347-957-3
Downloads: 81467
Price: Free* [*Free Regsitration Required]
Uploader: Mijin

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phonefaxor service astm. Hydrochloric acid fumes are present, and hydrogen gas is evolved in the stripping process.

Where a continuous length is not available, shorter lengths totaling over 12 in. NOTE 2—For convenience in calculating test results in inch-pound units, the specimen should have an area of 5. Alternatively, for specimens of uniform thickness of base metal, such as a piece of plate or pipe, determine the average thickness of the stripped specimen to the nearest 0.

Permission rights to photocopy the standard may also be secured from the ASTM website www. Specifications for zinc-coated articles frequently provide for different classes of coating so that the purchaser can select the coating weight [mass] most suitable to his needs.

This standard is subject to revision at any time by the responsible technical committee and must be reviewed every? Each of ten laboratories tested three replicates of two different materials. In the body of this test method, reference to zinc coating shall be interpreted to also include zinc alloy coating except where specifically stated otherwise.

  BRUCE FINK THE LACANIAN SUBJECT PDF

The specimen of wire may be of any length over 12 in. The mixing should be performed under an acid fume hood. When it is not possible to determine the area accurately, as in specimens from corrugated sheets, the thickness of the stripped sheet shall be determined to the nearest 0. Link to Active This link will always route to the current Active version of the standard.

If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below.

ASTM A90/A90M – 13(2018)

Current edition approved April 1, This requires about 15 to 30 s, except in the case of sherardized coatings, which require a somewhat longer time. A coating of zinc on iron or steel articles provides protection against corrosion.

Certain portions of the procedure involving determination of specimen weight [mass] have traditionally been performed in SI units, and corresponding inch-pound units are not included. Historical Version s astj view previous versions of standard. A fume hood is recommended for large numbers of samples or where the test is to be carried out frequently over extended periods of time.

ASTM A90 – ZINC PLATING WEIGHT ON STEEL

A number in parentheses indicates the year of last reapproval. A coating of zinc on iron or steel articles provides protection against corrosion. As the protection is provided by sacri? Mixing must be done by slowly adding sulfuric acid to water due to the heat generated and possible splashing. The weight [mass] of coating in grams on a atsm of that area is numerically equal to the weight [mass] of coating in ounces per square foot of sheet.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  JOE CELKO SQL FOR SMARTIES PDF

Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. Except as otherwise provided, the specimens should z90 a minimum area x90 3 in.

Since the density of the steel is known 0. Certain portions of the procedure involving determination of specimen weight [mass] have traditionally been performed in SI units, and corresponding inch-pound units are not included. Referenced Documents purchase separately The documents listed below are referenced within the subject adtm but are not provided as part of the standard.

Therefore, the test should be performed under conditions of adequate ventilation. Under no circumstances should the water be added to the acid.

Unless otherwise indicated, it is intended that all reagents shall conform to the speci? ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

For results to be reported in metric units, the specimen should have an area of mm2 of sheet Originally approved in For very small items, several pieces may have to be stripped to obtain the minimum area.

ASTM A90/A90M 13镀锌和镀锌合金钢铁制品镀层重量的试验方法_百度文库

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM Ashm Headquarters. The same solution may be used repeatedly until the time required for stripping becomes inconveniently long. Determine the weight [mass] of the specimens again, to the same precision as in the initial determination.